Tr?id=1160200101807817&ev=PageView&noscript=1

CAT Marine Generator Set C9.3

C9.3 ACERT genset packages with heat exchanger or keel cooling are available with60 Hertz ratings of 250 ekW (313 kVA) and 300 ekW (375 kVA) and 50 Hz ratings of 200 ekW (250 kVA) and 250 ekW (313 kVA). Radiator cooled gen sets are with 60 Hz ratings of 224 ekW (280 kVA) and 274 ekW (343 kVA) and 50 Hz ratings of 185 ekW (231 kVA) and 235 ekW (294 kVA). The C9.3 propulsion, auxiliary, and generator set engines have a common rail fuel system for optimal combustion and lower emissions. Cooling system options for the propulsion and auxiliary engines include heat exchanger with sea water aftercooling, and keel with combined circuit or separate circuit aftercooling. The genset packages are available with heat exchanger, keel, or radiator cooling. These products are EPA Tier 3 and IMO II certified. In addition the propulsionengine ratings are EU Stage IIIA certified and auxiliary and gen sets are also CCNR Stage II certified.

Overview

C9.3 ACERT genset packages with heat exchanger or keel cooling are available with60 Hertz ratings of 250 ekW (313 kVA) and 300 ekW (375 kVA) and 50 Hz ratings of 200 ekW (250 kVA) and 250 ekW (313 kVA). Radiator cooled gen sets are with 60 Hz ratings of 224 ekW (280 kVA) and 274 ekW (343 kVA) and 50 Hz ratings of 185 ekW (231 kVA) and 235 ekW (294 kVA). The C9.3 propulsion, auxiliary, and generator set engines have a common rail fuel system for optimal combustion and lower emissions. Cooling system options for the propulsion and auxiliary engines include heat exchanger with sea water aftercooling, and keel with combined circuit or separate circuit aftercooling. The genset packages are available with heat exchanger, keel, or radiator cooling. These products are EPA Tier 3 and IMO II certified. In addition the propulsionengine ratings are EU Stage IIIA certified and auxiliary and gen sets are also CCNR Stage II certified.

  • Minimum Rating
    185R ekW (231 kVA) at 50hz, 224R ekW (280 kVA) at 60hz
  • Maximum Rating
    250R ekW (313 kVA) at 50hz, 300 ekW (375 kVA) at 60hz

  • Frequency
    50 Hertz & 60 Hertz

  • Speed
    1500 rpm @ 50Hz & 1800 rpm @ 60Hz

  • Emissions/Fuel Strategy
    EPA Tier 3, IMO II, EU IW

  • Engine Model
    C9.3
  • Aspiration
    Turbocharged Aftercooled
  • Bore
    105 mm
  • Stroke
    135 mm

  • Fuel System
    Common Rail

  • Excitation
    Permanent Magnet
  • Number of leads
    12-Lead 2 wires per lead
  • Insulation
    Class H
  • Drip Proof
    IP23
  • Voltage regulator
    approx. 0.5%

  • Length of Engine
    2170 mm
  • Width of Engine
    1260 mm
  • Weight (approximate)
    2367 kg

  • Height
    1436 mm