Tr?id=1160200101807817&ev=PageView&noscript=1

CAT® PMC-R Roof Support Control for Longwall Mining

The intrinsically-safe Cat® PMC-R control units are used on shearer or plow faces to provide medium to high level of longwall automation. Each Roof Support needs to be equipped with one PMC-R control unit and a solenoid driver to operate the in-shield hydraulic functions and a set of peripheral components, like sensors for pressures and shield advance. The PMC-R can control and display all functions of a shield and is simultaneously the interface between operator and machine (HMI). The PMC-R system can control all individual shield functions based on a reliable network. As an interactive system, it allows the user to execute single shield functions as well as automatic functions. Important process values are continuously displayed as feedback for the operator.

Overview

The intrinsically-safe Cat® PMC-R control units are used on shearer or plow faces to provide medium to high level of longwall automation. Each Roof Support needs to be equipped with one PMC-R control unit and a solenoid driver to operate the in-shield hydraulic functions and a set of peripheral components, like sensors for pressures and shield advance. The PMC-R can control and display all functions of a shield and is simultaneously the interface between operator and machine (HMI). The PMC-R system can control all individual shield functions based on a reliable network. As an interactive system, it allows the user to execute single shield functions as well as automatic functions. Important process values are continuously displayed as feedback for the operator.

  • Operating System
    µITRON RTOS
  • Processor
    16Bit Microcontroller TMP91CW12AF, 27MHz, internal RAM 4Kbytes, ROM 125Kbytes
  • RAM Memory
    2Mbytes CMOS Static RAM, 4Mbytes Flash

  • Height
    116.0 mm
  • Height
    116.0 mm
  • Height
    37.0 mm

  • Length
    320.0 mm
  • Length
    320.0 mm
  • Length
    347.0 mm

  • Width
    178.0 mm
  • Width
    178.0 mm
  • Width
    68.0 mm

  • Types
    Europe: ATEX
  • Types
    U.S.: MSHA
  • Types
    More certifications on demand
  • Types
    Australia: IECEx, ANZEx
  • Types
    China: MA
  • Types
    Russia: GOST

  • Socket S101 - Pin 1
    12.0 volts
  • Socket S101 - Pin 2 (Solenoid 1)
    TX
  • Socket S101 - Pin 3 (Solenoid 2)
    RX
  • Sockets S301-S306 - Pin 1
    12.0 volts
  • Sockets S301-S306 - Pin 2 (Solenoid 1)
    GND1
  • Sockets S301-S306 - Pin 3 (Solenoid 2)
    GND2
  • Sockets S301-S306 - Pin 4
    GND
  • Sockets S307-S311 - Pin 1
    12.0 volts
  • Sockets S307-S311 - Pin 2 (Solenoid 1)
    GND1
  • Sockets S307-S311 - Pin 3 (Solenoid 2)
    GND2
  • Sockets S307-S311 - Pin 4
    0 - 1 mA; 0.5 - 4.5 V

  • Supply Current - Maximum Ratings
    2.0 amps
  • Supply Current - Typical Value
    1.0 amps
  • Supply Voltage - Maximum Ratings
    9.5 V - 13.2 V
  • Supply Voltage - Typical Value
    12 V DC

  • Temperature - Maximum Ratings
    -20° C - +40° C (-4° F - +140° F)
  • Temperature - Symbol
    Tamb
  • Temperature - Typical Value
    20.0 ° C
Scroll to Top